Xantrex XHR 7.5-130 Programmable DC Power Supply 0-7.5V 0-130A w/ RS-232 OptionXantrex XHR 7.5-130 Programmable DC Power Supply 0-7.5V 0-130A w/ RS-232 OptionXantrex XHR 7.5-130 Programmable DC Power Supply 0-7.5V 0-130A w/ RS-232 OptionXantrex XHR 7.5-130 Programmable DC Power Supply 0-7.5V 0-130A w/ RS-232 OptionXantrex XHR 7.5-130 Programmable DC Power Supply 0-7.5V 0-130A w/ RS-232 OptionXantrex XHR 7.5-130 Programmable DC Power Supply 0-7.5V 0-130A w/ RS-232 Option
$840.00


Used, but clean, tested, and in good working condition. Includes the RS-232 digital programming interface option. The DMM is for testing only and not included.

The 1000 watt DC output power supplies provide low noise, precisely regulated, variable DC output. Typically they are used for bench and automated test equipment (ATE) applications. Each unit includes over voltage protection and thermal shutdown as standard features. Universal AC input allows you to use line voltages globally without resetting switches or adding options. Built-in power factor correction gives you full output power from low current/low voltage outlets, reduces power line interference, and allows you to meet international regulations. You can select from several remote control choices for either analog or digital control. For analog control, choose from standard analog control or optional 4-channel isolated programming. Digital control options include RS-232 control or GPIB programming. You can use the power supply on your benchtop or rack mounted; each supply occupies less than 3-1/2 in. (2 U) of vertical space. Whether you are powering batteries, development circuits, and magnet coils or running ATE systems, the power supply provides the precision and power that you need.

Features and Options

  • voltage Range: 0-7.5 Vdc; current range: 0-130 A.
  • Internal power factor correction allows operation from a standard 120 Vac, 15 A outlet.
  • Thermal shutdown, latching or auto reset.
  • Front panel control of Over Voltage Protection (OVP).
  • Simultaneous digital display of both voltage and current.
  • Ten-turn front panel voltage and current controls for high resolution setting of the output voltage and current from zero to the rated output.
  • Automatic mode crossover into current or voltage mode.
  • Front panel push button control of output standby mode, and preview of voltage, current, or OVP set points. Front panel LED indicators for voltage and current mode operation, OVP, remote programming mode, and shutdown.
  • Multiple units can be connected in parallel or in series to provide increased current or voltage. Remote analog voltage and current limit programming with selectable programming ranges.
  • External monitor signals for output voltage and current.
  • Isolated analog remote programming control of the output voltage or current and isolated readback of output voltage and current with the optional ISOL interface.
  • Optional internal GPIB or RS-232 computer control for complete remote programming and readback capability.

Specifications

  • Output Ratings: Output Voltage - 0-7.5 V; Output Current - 0-130 A; Output Power - 975 W
  • At the front panel binding posts: Output Current - 0-30 A; Output Power - 225 W
  • Line Regulation: Voltage (0.01% of Vmax + 2 mV) - 3 mV; Current (0.01% of Imax + 1 mA) - 14 mA (For input voltage variation over the AC input voltage range, with constant rated load.)
  • Load Regulation: Voltage (0.01% of Vmax + 2 mV) - 3 mV; Current (0.05% of Imax + 1 mA) - 66 mA; At the front panel binding posts: Voltage - 650 mV (For 0-100% load variation, with constant nominal line voltage. Measured at the rear panel output connector unless stated otherwise.)
  • Meter Accuracy: Voltage (1% of Vmax + 1 count) - 0.09 V; Current (1% of Imax + 1 count) - 1.4 A
  • Output Noise and Ripple (V): rms - 10 mV; p-p (0-20 MHz) - 70 mV; At the front panel binding posts: p-p (0-20 MHz) - 250 mV
  • Drift (8 hours): Voltage (0.05% of Vmax) - 3.75 mV; Current (0.1% of Imax) - 130 mA (Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up.)
  • Temperature Coefficient: Voltage (0.02% of Vmax/°C) - 1.5 mV; Current (0.03% of Imax/°C) - 39 mA (Change in output per °C change in ambient temperature, with constant line and load.)
  • Maximum Remote Sense Line Drop Compensation: 3 V/line ( Line drop is subtracted from total voltage available at supply output.)
  • OVP Adjustment Range: (5% to 110% of Vmax) 0.375-8.25 V
  • Efficiency: 81% (Typical efficiency at 115 Vac input and rated output power.)
  • Voltage Mode Transient Response (Time for the output voltage to recover within 0.5% of its previous level after a step change in load current of up to 50% of the rated output.): 1 ms
  • Time delay from power on until output stable: 4 s maximum
  • Rated AC Input Voltage: 100/120/200/220/230/240 Vac (nominal)
  • Maximum AC Input Rating: 1300 VA
  • Operational AC Input Voltage Range: 85-250 Vac; power factor corrected. Derate maximum output power to 900 W for AC input less than 95 V.
  • Maximum Input Current: 13 A maximum at 100 Vac, 11 A maximum at 120 Vac, 6 A maximum at 220 Vac.
  • Input Frequency Range 47-63 Hz
  • Power Factor: 0.99 minimum for full load and 120 Vac input
  • Switching Frequency: nominal 125 kHz (250 kHz output ripple)
  • Output Hold-up: Time Greater than 10 ms with interruption of AC line, for nominal AC input and full load.
  • Maximum Voltage Differential from output to safety ground: ±600 Vdc
  • Isolation Voltage: Input to output: 1350 Vac
  • Remote Start/Stop and Interlock: 2.5-15 V signal or TTL-compatible input, selectable logic. Input impedance: 1 k (in series with one diode drop).
  • Remote Analog Programming (Full Scale Input): Voltage and current programming inputs (source must be isolated): 0-5 k, 0-10 k resistances; 0-5 V (default), 0-10 V voltage sources; Input impedance (V and I): approximately 475 k.
  • Remote monitoring: Output voltage and current: 0-5 V, 0-10 V (default); Output impedance (V and I): approximately 221; Output short circuit current: approximately 50 mA.
  • Remote Programming and Monitoring Accuracy: 1% zero to full scale output for the default range.
  • Maximum Remote Sense Line Drop Compensation. (Line drop must be deducted from the supply's maximum output voltage.): 3 V/line
  • Isolated Program and Readback (V & I) (Optional): 0-5 V (ISOL interface). Input impedance: 200 k. Output impedance: 21
  • Digital Control: RS-232
  • Front Panel Voltage and Current Control: 10-turn voltage and current potentiometers
  • Front Panel Voltage Control Resolution: 0.02% of maximum voltage
  • Front Panel Voltage and Current Meters: 3.5-digit numeric LED displays
  • AC Input Connector: Type IEC 320 Connector
  • Front Panel Output: 5-way binding posts: maximum current limit 30 A
  • OVP Control: Screwdriver-set potentiometer on front panel
  • Input Fuses: 20 A, 250 V, 5 x 20 mm slow fuses, location: A5 PCB, F321, 325; 0.005 A, 250 V, 5 x 20 mm fast fuse, location: A3 PCB, F1.
  • Main Output Connector: nickel-plated copper bus bars
  • Analog Programming, Monitoring, and Sense Connector (2-piece): 12-terminal wire clamp connector
  • Chassis Ground: Chassis ground screw located on rear panel for bonding connections
  • Cooling: Fan cooled. Air exhausts to rear. Over temperature shutdown: automatic restart or latch off (switch-selectable).
  • Mounting Optional rack mount pan. (RM3-XHR)
  • Size: 87.0 mm H x 214.6 mm W x 472.2 mm D (3.425in. H x 8.45in. W x 18.59in. D)
  • Weight: Approximately 6.4 kg (14 lb.)