Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-
Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-Binder C02 O2 N2 Incubator CB210-UL, 7.5 Cu Ft (210L) -5 Day Temp & CO2 Tested-
$2,250.00

Clean and in excellent condition. Heating temperature and stability was tested over a 5-Day period.

This unit was removed from a high profile national laboratory during an upgrade. All equipment released from this facility goes through a rigorous decontamination certification process prior to removal.

The system performed beautifully. Controls functioned as designed. CO2 tested in our facility. Sensor and solenoid reacted appropriately, maintaining setpoint with minimal variance over the duration of our tests. We did not have an oxygen tank on hand but the O2 sensor responded correctly to environmental changes, dipping from 21% to 19% when displaced by CO2. 

This unit is configured for use with a 120V, 20A circuit. It is mounted in a heavy duty frame suitable for stacking units. Operations manual included.

CO2 tanks and regulator shown in photos were for testing purposes and are not included with purchase.

Hassle-free warranty.


Manufacturer Description

CO2 incubator with additional process controls

The BINDER CB series CO2 incubator is the premium class among the CO2 incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth. A BINDER CO2 incubator of the CB series is up to even complex cultivation experiments or individual environments.

Advantages:
  • Hot air sterilization at 180 °C
  • Seamless, deep-drawn inner chamber made of stainless steel
  • Unique BINDER technology (patented air jacket system, controlled condensation, etc.)

 

Areas of application:
  • Bio Tissue Engineering
  • In vitro Fertilization (IVF)
  • Clinics / University Hospitals

 

Features Customer benefits Characteristics
Sterilization
  • Complete elimination of bacteria, spores, etc.
  • Reliable sterilization of the atmosphere and all surfaces
  • Minimal sterilization costs

180 °C hot air sterilization

  • Standards compliance, meets all relevant standards
  • Automatic sterilization process
Permadry™ humidity system
  • Uniform osmotic cell pressure
  • Optimum cell growth even with microwell plates
  • No Provides no sources of contamination.

Controlled humidification system

  • Defined recondensation point
  • Dry interior walls
  • High humidity
  • Rapid humidity recovery times
  • Simple water exchange through water pan
APT.line™ heating technology
  • Optimal, uniform cell growth throughout the inner chamber

Preheating chamber with VENTAIR™ air jacket

  • Homogeneous temperature distribution
  • Rapid recovery after temperature drop
  • Accurate temperature control
Gas distribution
  • Stable pH value

Gas mixing head with venturi effect

  • Homogeneous CO2 distribution
  • Fast effective aeration
Inner chamber concept
  • Easy cleaning
  • Fully usable volume 53, 150, 210 l
  • No Provides no sources of contamination.

Seamless, deep-drawn inner chamber

  • Integrated shelf support system
  • Burr-free stainless steel perforated sheets with tilt protection
CO2 measurement
  • Stable pH value even with frequent door opening
  • Long-term stable system
  • Low maintenance costs

Single-beam infrared sensor

  • Rapid response time
  • Measures CO2 in real-time
  • Independent of gas and humidity
Operating costs
  • Minimal operating costs
  • Time savings
  • Minimal work and material costs for sterilization

 

Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and best cell growth

  • Temperature range from 7 °C above ambient temperature to 60 °C
  • MCS controller for temperature and CO2 concentration
  • User-friendly LCD screen
    • Easy-to-read menu guide
    • Integrated electronic chart recorder
    • Variety of options for the graphic display of process parameters
    • Real time clock
  • Standard-compliant hot air sterilization at 180 °C (DIN 58947)
  • VENTAIR™ Jacket System
  • Drift-free infrared CO2 measurement system
  • Patended Gas mixing nozzle
  • Permadry System - condensation-free double-pan humidification system, maintains dry interior walls
  • Seamless deep-drawn inner chamber made of stainless steel with integrated shelf support system (flanges)
  • Electronic self-diagnostic system for errors with visual and audible alarms, as well as relay potential changeover contact for central monitoring
  • Independent temperature safety device class 3.1 (DIN 12880) with optical and audible temperature alarm
  • Tightly-fitted inner glass door
  • RS 422 interface for communication software APT-COM™ DataControlSystem
  • 2 perforated stainless steel shelves with standard equipement and O2 control
  • Units are stackable with stacking adapter
  • Door lock
  • BINDER test confirmation

 

CB 210
  Exterior dimensions  
  Width (mm) 740
  Height (incl. feet) (mm) 1070
  Depth (plus 54 mm for door handle and connection) (mm) 715
  Wall clearance side / rear (mm) 50 / 100
  Number of doors (ea.) 1
  Inner glass door(s) 1
     
  Interior dimensions  
  Width (mm) 560
  Height (mm) 750
  Depth (mm) 500
  Interior volume (l) 210
  Stainless steel shelf (number standard/max.) 3 / 8
  Dimensions of shelf, width x depth (mm) 555,5 x 444
  Load per shelf (kg) 10
  Permitted total load (kg) 30
  Weight (empty) (kg) 121
     
  Temperature data  
  Temperature range approx. 7 °C above ambient temperature to (°C) 60
  Temperature variation at 37 °C (± K) 0,4
  Temperature fluctuation (± K) 0,1
  Recovery time after door was opened for 30 sec. at 37 °C (min) 1) 3
     
  Humidity data  
  Humidity (±2% r.h.) 95
     
  CO2 data  
  CO2 range (% CO2) 0-20
  Setting accuracy (Vol.-% CO2) 0,1
  Recovery time after door was opened for 30 sec. at 5 vol. % (min.) 1) 9
  CO2 measurement IR
  Connection hose nozzle for CO2 DN 6 for hose with internal diameter (mm) 6
     
  O2 data  
  O2 range (Vol.-% O2) 0,2 - 95
  Setting accuracy (Vol.-% O2) 0,1
  Recovery time after door was opened for 30 sec. (min.) 1)  
  at 1.0 vol. % O2 (min.) 54
  at 5.0 vol. % O2 (min.) 11
  O2 measurement ZrO2
  Gas connection hose nozzle for O2 / N2 DN 6 for hose with internal diameter (mm) 6
     
  Electrical data  
  Voltage (± 10%) 50 / 60 Hz (V) 230
  Nominal power (kW) 1,5
  Energy consumption at 37 °C (W) 2) 130

1) up to 98 % of the set value
2) These values can be used for dimensioning air condition systems.