$2,800.00

Clean and in excellent condition. Removed from a high profile state lab during an upgrade, this workstation was well maintained under a regularly scheduled service contract.

System booted and passed extended self test without error. Incubator temp control functioned perfectly and all menu operations responded as designed. Sample drawers all smoothly functional. We do not have the software and are unable to test clinical operations further but based on self test results and physical inspection, our standard warranty applies.

Comes as shown with power cable.

Hassle Free Warranty.



Manufacturer Description

FLEXstation Benchtop Scanning Fluorometer and Integrated Fluid Workstation

FLEXstation allows users to obtain real-time kinetic data milliseconds before and after fluid transfer events
FLEXstation allows users to obtain real-time kinetic data milliseconds before and after fluid transfer events. The ability to perform 96-well micraplate-to-microplate transfers offers the utmost flexibility for your drug discovery efforts.

Real-Time Kinetic Cell Analysis
Intrgrating optics, fluidics, and temperatire control, FLEXstation is ideal for kinetic, cell-based flourometric assays, such as measuring intracelluar calcium, membrane potential, and intracelluar pH. The key advantage of the system is that it delivers compounds and detects from wells of a microplate within milliseconds of addition.

The Molecular Devices FlexStation is a benchtop scanning fluorometer and integrated fluid transfer workstation capable of conducting endpoint, kinetic, lambda scan and well scan experiments in a multi-well plate format (6, 12, 24, 48 and 96-well) and fluidics transfer experiments in 96-well format.  The FlexStation is ideal for measuring the activity of Gq-coupled receptors via the detection of intracellular calcium release. With additional kits, the workstation can also be used for the measurement of fatty acid uptake, cyclic GMP and AMP levels, potassium ion channel flux, and membrane potential.


Specifications
Fluorescence Photometric
Emission Wavelength Range 375-850 nm
Excitation Wavelength Range 250-850 nm
Scanning Increments 1 nm
Sensitivity (Signal 3X STD DEV) Top Read 3 fmol/Well FITC
Sensitivity (Signal 3X STD DEV) Bottom Read 8 fmol/Well FITC*
Time-Resolved Fluorescence (384-well plate) 0.5 fmol/Well Eu-Ch*
Luminescence Photometric
Sensitivity 10 amol ALKPhos*
Wavelength Range 375-850 nm
General Photometric
Microplate Well Formats 6-, 12-, 24-, 48-, 96-, 384-Well
Detection Spot Size: Top Read 3.5 mm
Detection Spot Size: Bottom Read 1.5 mm
Lamp Life Exp. 2 Years, Warr. 1 Year
Mechanical
Read Time 96 Wells in < 15 sec.
Single-Column Read Frequency 1 Hz
Single-Well Read Time Frequency 20 Hz
Shaker Time 0 to 999 seconds
Size 58 cm (W), 40 cm (D), 49 cm (H)
Thermal (Read Chamber and Fluidics)
Temperature Chamber Range/Rate Ambient +1°C to 45°C in 20 mins.
Fluidics (96-Well Plates Only)
Max. Volume — 8 Ch. 200 μL
Dispense Max. Rate — 8 Ch. 208 μL/sec.
Precision @ 50 μL — 8 Ch. 2% CV
Precision @ 5 μL — 8 Ch. 8% CV
Electrical
Power Consumption 450 VA
Line Voltage and Frequency 90-240 VAC, 50-60 Hz