$1,200.00

Clean and in good condition. Pulled from an operational premiere state laboratory during an equipment upgrade. The system was routinely maintained and reported fully functional at time of removal. Some minor scratching on the outer surface but nothing that affects usability.

The pipette base station is included but no pipettes or tubes so testing only included the following:

Power/Boot - Passed
UI/Touch Screen - Passed
Self Test/Diagnostics - Passed up to the point of pipette detection

Firmware is version 1.06. Software 1.00.

Comes as shown with pipette station and power cable.

Hassle free warranty.



Manufacturer Description

Enables fast and efficient delivery of nucleic acids into all mammalian cell types, including primary, stem, and difficult-to-transfect cells. The flexible and open system allows the user to perform high-quality transfections using optimized or user-defined protocols in three simple steps with as few as 2 × 104 cells per reaction and a reaction time of just 1 second. A novel reaction chamber provides a dramatic increase in transfection efficiency and cell viability.

  • Up to 90% in many cell types, including difficult-to-transfect cells, primary, and stem cells
  • Easily transfect from 2 × 104 cells to 6 × 106 cells per reaction
  • Easy to use, with a single reagent kit for all cell types
  • Open system allows electroporation parameters to be optimized freely
  • One-of-a-kind electroporation
  • Plug-n-play out of the box
  • Perform more transfections with limited or precious cells

For use at room temperature under normal laboratory conditions.

Adenoviral shRNA, Cell Culture, Lentiviral shRNA & miRNA, Plasmid Transfection, RNAi, RNAi Transfection, RNAi, Epigenetics & Noncoding RNA Research, Retroviral RNAi, Stem Cell & Primary Cell Transfections, Synthetic siRNA Transfection, Transfection, Vector-Based RNAi, siRNA

Specifications

3.0-6.0 A
The Neon™ Transfection System comes with a Neon™ electroporation device, pipette, pipette station, USB thumbdrive, manual and power cord.

For use at room temperature under normal laboratory conditions.
6-well Plate, 12-well Plate, 24-well Plate, 48-well Plate, 96-well Plate, Flasks
Neon™ Transfection System
0.5-2.5 kV
Transfection System
1 Ea.
Yes
2x10^4 - 6 x10^8 cells; Varies by cell type
100-240 VAC
Depends on kit used
Animal Origin-Free, Chemically Defined, Low-Protein, Xeno-Free, Reduced Growth Factors, Reduced Serum
Stem Cells, Primary Cells, Hard-to-Transfect Cells
Plasmid DNA, Synthetic siRNA
Transfection
Neon™
Transfection Grade
1 sec
Room Temperature
Neon™ Transfection System
300 W